Medication Preparation and Dispensing: Introduction 101
SKS Medication Safety Series, Chapter 7 of 15 · Standard SİY06
Prof. Dr. Mehmet Nurullah Kurutkan, Düzce Üniversitesi İşletme Fakültesi Sağlık Yönetimi Bölümü
Chapter at a glance
Between the order and the bedside, medicines are picked, divided, labelled and sometimes compounded. Each of these steps can introduce errors. This chapter covers dispensing errors, unit dose systems, pharmacy automation and the preparation of intravenous and cytotoxic medicines. It corresponds to SKS SİY06 (Sağlık Bakanlığı, 2020).
Evidence base: 361 records of a 4948-record Web of Science corpus on hospital medication safety (Section 7). Reading time: about 25 minutes. Prior knowledge required: none.
Learning objectives
After working through this chapter, the reader should be able to:
- state the SKS SİY06 requirements for preparation and dispensing;
- describe the frequency and causes of dispensing errors;
- evaluate bar code, unit dose and robotic technologies;
- explain why intravenous and chemotherapy preparation are high-risk.
Key concepts
- Dispensing error: a discrepancy between the order and the medicine supplied
- Unit dose system (Birim doz): supply of each dose individually packaged and labelled per patient
- Bar code verification: scanning to confirm the product picked
- Compounding: preparing a medicine from components, for example IV admixtures
- Gravimetric control: checking preparation accuracy by weight
Contents: How this chapter was produced · 1. Introduction · 2. History and development · 3. Definitions and conceptual schema · 4. Distinguishing it from neighbouring concepts · 5. Types and classifications · 6. Theoretical frameworks and models · 7. Themes and bibliometric profile · 8. The situation in Türkiye · 9. Debates and contradictions in the literature · 10. Measurement problems · 11. Research gaps and agenda · 12. Implications for practice today · Summary · Discussion questions · Further reading · Glossary · References · Source verification and AI use statement · Data and supplementary material
How this chapter was produced
Box 1. Method
Database: Web of Science Core Collection (SCI-EXPANDED, SSCI, ESCI); English; articles and reviews (including early access). Search date: 16 November 2026; all years (1981 to 2027).
Search: (#1 medication safety and error terms AND #2 hospital settings AND #3 fifteen SKS content blocks) NOT #4 animal and preclinical terms; the full string is on the series hub.
Screening: five export files (4955 records) were merged; 7 duplicates were removed by WoS accession number, DOI and normalised title plus year, leaving 4948 records. Records were assigned to this sub-topic when its term set (unit dose, dispensing, preparation, compounding, chemotherapy preparation, cytotoxic, admixture, reconstitution) appeared in the title or keywords; a record can belong to several sub-topics. Included here: 361 records (228 with the term in the title; 49 reviews).
Limitations: single database; English only; assignment by term matching, checked by reading titles of the most cited and most recent records; claims are checked against abstracts, not full texts.
4955 records
228 title matches; 49 reviews
other chapters or general records
1. Introduction
SKS requires an arrangement for medicines leaving the pharmacy; division into unit doses packaged separately for each patient with the drug name, form, dose and patient details on the package; separate labelling of split blister packs with patient identifiers, full drug name, pharmaceutical form, dose, time, route and expiry; and preparation of drugs that need special technique, equipment or expertise, such as chemotherapy, by a qualified person under suitable conditions (Sağlık Bakanlığı, 2020).
Dispensing errors are not rare: in a UK hospital pharmacy they occurred in about 2% of dispensed items, and about one in a hundred of these escaped the final check (Beso et al., 2005).
2. History and development
The oldest records study checking of unit dose cassettes by technicians (Woller et al., 1991) and the effect of lighting on dispensing errors (Buchanan et al., 1991). Interruptions and distractions were linked to errors in 1999 (Flynn et al., 1999). Bar code technology in the pharmacy substantially reduced dispensing errors in 2006 (Poon et al., 2006), and an automated dispensing system reduced errors in intensive care in 2010 (Chapuis et al., 2010). The last decade brought systematic reviews of automation (Batson et al., 2021; Hänninen et al., 2023) and of chemotherapy compounding technology (Batson et al., 2020).
- 1991 Lighting levels linked to dispensing error rates (Buchanan et al., 1991).
- 1999 Interruptions and distractions associated with dispensing errors (Flynn et al., 1999).
- 2005 Multicentre audit of IV preparation and administration errors in three countries (Cousins et al., 2005).
- 2006 Pharmacy bar code scanning reduces dispensing errors (Poon et al., 2006).
- 2010 Automated dispensing reduces ICU preparation errors (Chapuis et al., 2010).
- 2017 Gravimetric and double-check methods compared for chemotherapy (Carrez et al., 2017).
- 2023 Systematic review of automated unit dose systems (Hänninen et al., 2023).
3. Definitions and conceptual schema
| Source | Year | Discipline | Definition (paraphrased) | Emphasised dimension |
|---|---|---|---|---|
| Sağlık Bakanlığı, 2020 | 2020 | Accreditation standard | Unit dose division and patient-specific labelling, with special preparation by qualified staff for drugs such as chemotherapy. | Packaging and labelling |
| Beso et al., 2005 | 2005 | Hospital pharmacy | Dispensing error as a discrepancy detected at the final check or after the item left the pharmacy. | Detection stage |
| Hänninen et al., 2023 | 2023 | Pharmacy automation | Automated unit dose systems producing individually packaged and labelled drugs for inpatients. | Automation |
| Cousins et al., 2005 | 2005 | Patient safety | IV preparation as a high-risk activity requiring risk management. | Risk level |
| Carrez et al., 2017 | 2017 | Oncology pharmacy | Preparation reliability as dose accuracy verified by double check or gravimetric control. | Accuracy verification |
the medicine leaving pharmacy or preparation areas matches the order exactly and carries the information needed for safe administration
The common core is fidelity to the order. Definitions diverge between environment-based explanations (Flynn et al., 1999) and technology-based solutions (Hänninen et al., 2023).
4. Distinguishing it from neighbouring concepts
Preparation and dispensing overlap with administration, prescribing and storage (Figure 4), reflecting closed-loop systems that link all three.
| Neighbouring concept | How it differs |
|---|---|
| Storage (SİY04) | Concerns conditions before picking; dispensing concerns the act of supply (Rodriguez-Gonzalez et al., 2019). |
| Administration (SİY08) | Ward preparation of IV doses straddles both chapters (Cousins et al., 2005). |
| Transport (SİY07) | Starts after dispensing (Ahtiainen et al., 2020). |
| Controlled drugs (SİY11) | A dispensing subset with legal documentation (Zheng et al., 2021). |
5. Types and classifications
Systems range from manual picking with final check (Beso et al., 2005) through bar code-assisted dispensing (Poon et al., 2006) to automated unit dose robots (Hänninen et al., 2023). Preparation includes ward-level IV preparation by nurses (Dougherty et al., 2012) and centralised compounding, increasingly with workflow systems or robots (Iwamoto et al., 2017; Moniz et al., 2014).
6. Theoretical frameworks and models
Ergonomic and human factors models dominate: lighting (Buchanan et al., 1991), interruptions (Flynn et al., 1999) and decision-making during IV preparation (Dougherty et al., 2012). Reviews of automation adopt a health technology assessment logic of clinical and economic value (Batson et al., 2021).
7. Themes and bibliometric profile
Figure 5 shows steady growth. Bar code technology reduced dispensing errors, provided it was configured to scan every dose (Poon et al., 2006). An automated system reduced picking and preparation errors in intensive care but did not reduce errors causing harm (Chapuis et al., 2010). For chemotherapy, only gravimetric control detected all dose errors, though it did not improve accuracy (Carrez et al., 2017).
Records per year 2026 (incomplete)
Most frequent journals
Most frequent countries
Most frequent author keywords: medication errors (97), patient safety (45), medication safety (41), medication error (35), dispensing (34), automation (24), hospital pharmacy (23), compounding (19), pharmacy (19), pharmacy, institutional, hospital (19).
8. The situation in Türkiye
Two records have Turkish authors: a robotic system to prepare IV solutions, which allows unused drug in vials to be used and saves purchasing costs (Unluturk et al., 2018), and an observational study that found a very high interruption rate during medication preparation, mainly caused by the treatment room environment (Duruk et al., 2016).
9. Debates and contradictions in the literature
Automation or people? Reviews conclude that more adequately powered studies with clinically relevant outcomes are needed before firm recommendations on return on investment (Batson et al., 2021; Hänninen et al., 2023).
Double check or technology? Independent double checking is common but less reliable than gravimetric control for chemotherapy doses (Carrez et al., 2017).
Central or ward preparation? IV preparation errors vary with national systems for preparation and administration (Cousins et al., 2005).
10. Measurement problems
Error rates depend on whether errors are counted at the final check or after supply (Beso et al., 2005). Direct observation is standard for IV preparation but costly (Cousins et al., 2005). Few studies link dispensing errors to harm (Chapuis et al., 2010).
11. Research gaps and agenda
- How do interruptions in Turkish preparation rooms translate into errors and harm? (Duruk et al., 2016)
- What is the cost-effectiveness of IV robots in Turkish hospitals? (Unluturk et al., 2018)
- Do automated unit dose systems reduce harm, not only errors? (Hänninen et al., 2023)
- Which verification method is optimal for paediatric IV doses? (Moniz et al., 2014)
- How should SKS unit dose labelling be audited?
12. Implications for practice today
Create quiet zones for preparation (Duruk et al., 2016; Flynn et al., 1999); configure bar code scanning for every dose (Poon et al., 2006); use gravimetric or workflow systems for chemotherapy (Carrez et al., 2017; Moniz et al., 2014); and evaluate automation with clear clinical outcomes before investing (Batson et al., 2021).
Summary
- Dispensing errors occur in about 2% of items in one UK study.
- SKS SİY06 requires unit dose packaging and patient-specific labels.
- Bar codes and automation reduce errors, not always harm.
- IV and chemotherapy preparation are high-risk steps.
- Interruptions are a key, modifiable cause.
Discussion questions
- Why must bar code systems scan every dose?
- Compare double checking with gravimetric control.
- How would you reduce interruptions in a ward preparation room?
- Assess whether an IV robot is justified for a 400-bed hospital.
- Which labelling errors would SKS surveyors look for?
Further reading
- (Poon et al., 2006): the classic bar code dispensing study.
- (Beso et al., 2005): frequency and causes of dispensing errors.
- (Cousins et al., 2005): international audit of IV preparation.
- (Hänninen et al., 2023): current evidence on automated unit dose systems.
- (Carrez et al., 2017): verification methods for chemotherapy.
Glossary
| Turkish | English | Short definition |
|---|---|---|
| Dağıtım hatası | Dispensing error | Discrepancy between order and supplied medicine |
| Birim doz | Unit dose | Individually packaged patient dose |
| Barkod doğrulama | Bar code verification | Scanning to confirm the product |
| Hazırlama (karışım) | Compounding | Preparing a medicine from components |
| Gravimetrik kontrol | Gravimetric control | Checking accuracy by weight |
References
Ahtiainen, H. K., Kallio, M. M., Airaksinen, M., & Holmström, A. R. (2020). Safety, time and cost evaluation of automated and semi-automated drug distribution systems in hospitals: a systematic review. European Journal of Hospital Pharmacy, 27(5), 253-262. https://doi.org/10.1136/ejhpharm-2018-001791
Batson, S., Herranz, A., Rohrbach, N., Canobbio, M., Mitchell, S. A., & Bonnabry, P. (2021). Automation of in-hospital pharmacy dispensing: a systematic review. European Journal of Hospital Pharmacy, 28(2), 58-64. https://doi.org/10.1136/ejhpharm-2019-002081
Batson, S., Mitchell, S. A., Lau, D., Canobbio, M., De Goede, A., Singh, I., & Loesch, U. (2020). Automated compounding technology and workflow solutions for the preparation of chemotherapy: a systematic review. European Journal of Hospital Pharmacy, 27(6), 330-336. https://doi.org/10.1136/ejhpharm-2019-001948
Beso, A., Franklin, B. D., & Barber, N. (2005). The frequency and potential causes of dispensing errors in a hospital pharmacy. Pharmacy World & Science, 27(3), 182-190. https://doi.org/10.1007/s11096-004-2270-8
Buchanan, T. L., Barker, K. N., Gibson, J. T., Jiang, B. C., & Pearson, R. E. (1991). Illumination and errors in dispensing. American Journal of Hospital Pharmacy, 48(10), 2137-2145. https://doi.org/10.1093/ajhp/48.10.2137
Carrez, L., Bouchoud, L., Fleury-Souverain, S., Combescure, C., Falaschi, L., Sadeghipour, F., & Bonnabry, P. (2017). Reliability of chemotherapy preparation processes: Evaluating independent double-checking and computer-assisted gravimetric control. Journal of Oncology Pharmacy Practice, 23(2), 83-92. https://doi.org/10.1177/1078155215620001
Chapuis, C., Roustit, M., Bal, G., Schwebel, C., Pansu, P., David-Tchouda, S., Foroni, L., Calop, J., Timsit, J. F., Allenet, B., Bosson, J. L., & Bedouch, P. (2010). Automated drug dispensing system reduces medication errors in an intensive care setting. Critical Care Medicine, 38(12), 2275-2281. https://doi.org/10.1097/CCM.0b013e3181f8569b
Cousins, D. H., Sabatier, B., Begue, D., Schmitt, C., & Hoppe-Tichy, T. (2005). Medication errors in intravenous drug preparation and administration: a multicentre audit in the UK, Germany and France. Quality & Safety in Health Care, 14(3), 190-195. https://doi.org/10.1136/qshc.2003.006676
Dougherty, L., Sque, M., & Crouch, R. (2012). Decision-making processes used by nurses during intravenous drug preparation and administration. Journal of Advanced Nursing, 68(6), 1302-1311. https://doi.org/10.1111/j.1365-2648.2011.05838.x
Duruk, N., Zencir, G., & Eser, I. (2016). Interruption of the medication preparation process and an examination of factors causing interruptions. Journal of Nursing Management, 24(3), 376-383. https://doi.org/10.1111/jonm.12331
Flynn, E. A., Barker, K. N., Gibson, J. T., Pearson, R. E., Berger, B. A., & Smith, L. A. (1999). Impact of interruptions and distractions on dispensing errors in an ambulatory care pharmacy. American Journal of Health-System Pharmacy, 56(13), 1319-1325. https://doi.org/10.1093/ajhp/56.13.1319
Hänninen, K., Ahtiainen, H. K., Suvikas-Peltonen, E. M., & Tötterman, A. M. (2023). Automated unit dose dispensing systems producing individually packaged and labelled drugs for inpatients: a systematic review. European Journal of Hospital Pharmacy, 30(3), 127-135. https://doi.org/10.1136/ejhpharm-2021-003002
Iwamoto, T., Morikawa, T., Hioki, M., Sudo, H., Paolucci, D., & Okuda, M. (2017). Performance evaluation of the compounding robot, APOTECAchemo, for injectable anticancer drugs in a Japanese hospital. Journal of Pharmaceutical Health Care and Sciences, 3, Article 12. https://doi.org/10.1186/s40780-017-0081-z
Moniz, T. T., Chu, S., Tom, C., Lutz, P., Arnold, A., Gura, K. M., & Patterson, A. (2014). Sterile product compounding using an i.v. compounding workflow management system at a pediatric hospital. American Journal of Health-System Pharmacy, 71(15), 1311-1317. https://doi.org/10.2146/ajhp130649
Poon, E. G., Cina, J. L., Churchill, W., Patel, N., Featherstone, E., Rothschild, J. M., Keohane, C. A., Whittemore, A. D., Bates, D. W., & Gandhi, T. K. (2006). Medication dispensing errors and potential adverse drug events before and after implementing bar code technology in the pharmacy. Annals of Internal Medicine, 145(6), 426-434. https://doi.org/10.7326/0003-4819-145-6-200609190-00006
Rodriguez-Gonzalez, C. G., Herranz-Alonso, A., Escudero-Vilaplana, V., Ais-Larisgoitia, M. A., Iglesias-Peinado, I., & Sanjurjo-Saez, M. (2019). Robotic dispensing improves patient safety, inventory management, and staff satisfaction in an outpatient hospital pharmacy. Journal of Evaluation in Clinical Practice, 25(1), 28-35. https://doi.org/10.1111/jep.13014
Sağlık Bakanlığı. (2020). Sağlıkta kalite standartları: Hastane (Sürüm 6.1). Sağlık Hizmetleri Genel Müdürlüğü, Sağlıkta Kalite, Akreditasyon ve Çalışan Hakları Dairesi Başkanlığı. https://dosyamerkez.saglik.gov.tr/Eklenti/41258/0/skshastane-seti-s-61–09082021pdf.pdf
Unluturk, M. S., Tamer, O., & Utku, S. (2018). A robotic system to prepare IV solutions. International Journal of Medical Informatics, 119, 61-69. https://doi.org/10.1016/j.ijmedinf.2018.09.011
Woller, T. W., Stuart, J., Vrabel, R., & Senst, B. (1991). Checking of unit dose cassettes by pharmacy technicians at 3 Minnesota hospitals. American Journal of Hospital Pharmacy, 48(9), 1952-1956. https://doi.org/10.1093/ajhp/48.9.1952
Zheng, W. Y., Lichtner, V., Van Dort, B. A., & Baysari, M. T. (2021). The impact of introducing automated dispensing cabinets, barcode medication administration, and closed-loop electronic medication management systems on work processes and safety of controlled medications in hospitals: A systematic review. Research in Social & Administrative Pharmacy, 17(5), 832-841. https://doi.org/10.1016/j.sapharm.2020.08.001
Source verification and AI use statement
Source verification. All 20 references were generated programmatically from the Web of Science records of the corpus, so authors, year, title, journal and DOI match the records exactly; every in-text citation was cross-checked by code against the reference list. Claims were checked against the record abstracts; full texts were not read. The SKS Hospital Set (Version 6.1) is the only source outside the corpus; it was accessed and read for this chapter.
AI use statement. Claude (Anthropic) was used to merge and de-duplicate the Web of Science exports, assign records to sub-topics, compute the bibliometric indicators and figures, and draft the text under the author’s instructions. The author is responsible for the final content.
Data and supplementary material
Supplementary file S1 (Excel) lists the 361 records of this chapter (authors, year, title, journal, DOI, title match flag), together with the full screening log of the 4948-record corpus and the citation verification report. The list is not reproduced here; it is available from the author on request.
← Chapter 6: Prescribing and Medication OrdersChapter 8: Medication Transport and Distribution →