NPG #14 Part 4 cover: Perioperative and Procedural Medication Labeling, Introduction 101

Perioperative and Procedural Medication Labeling: An Introduction (101)

In brief: NPG #14 requires that all medications, medication containers (syringes, cups, basins) and other solutions on and off the sterile field in perioperative and procedural settings are labeled when not immediately administered, at the moment of transfer and as soon as they are prepared; labels include name, strength, amount, diluent and volume, and expiry date and time (Joint Commission, 2025). Direct observation shows that about one in 20 perioperative medication administrations involves an error or adverse drug event (Nanji et al., 2016).

Prof. Dr. Mehmet Nurullah Kurutkan, Düzce University, Faculty of Business, Department of Health Management

Abstract. Part 4 addresses the labeling requirement of NPG #14 in operating rooms and procedural areas. Based on 302 hospital records in a 4,936-record Web of Science corpus, it explains why unlabeled syringes and basins are a recurrent cause of serious errors, defines compliant labeling, and places it within the wider science of perioperative medication safety: syringe swaps, prefilled syringes, barcode label systems, Tall Man lettering and label design. The evidence shows high error frequencies by direct observation, consistent human-factors support for better labels, and moderate adoption of technological solutions in practice.

Learning objectives

After completing this chapter, the reader will be able to:

  1. State the five labeling elements and three timing rules required by NPG #14.
  2. Explain why the perioperative setting carries a high risk of medication error.
  3. Distinguish labeling from neighbouring safeguards such as barcode scanning, prefilled syringes and Tall Man lettering.
  4. Summarise the evidence on perioperative and anaesthetic drug administration errors.
  5. Evaluate human-factors studies of label design.
  6. Design an audit of labeling compliance in an operating theatre.

Key concepts: sterile field, syringe swap, drug administration error, prefilled syringe (PFS), barcode label system, Tall Man lettering, look-alike sound-alike (LASA), perioperative medication management

Contents

  • 1. Introduction
  • 2. History and development
  • 3. Definitions and conceptual schema
  • 4. Distinguishing neighbouring concepts
  • 5. Types and classifications
  • 6. Theoretical frameworks and models
  • 7. Themes and bibliometric profile
  • 8. The situation in Türkiye
  • 9. Debates and contradictions in the literature
  • 10. Measurement problems
  • 11. Research gaps and agenda
  • 12. Relevance today and practical implications
  • Summary box, discussion questions, further reading, glossary and references

Method box: how this chapter was produced

ComponentApplication
Source documentJoint Commission (2025), National Performance Goal #14 “Effectively Managing Medications” (formerly part of the National Patient Safety Goals). (Joint Commission, 2025)
Database and indexesWeb of Science Core Collection (SCI-EXPANDED, SSCI, ESCI)
Search strategy (series)Seven component blocks derived from the NPG #14 requirements, a core medication safety block and a hospital context block; combined set #24 = ((#1 AND component blocks 1-4) OR medication reconciliation OR anticoagulant block) AND hospital block, OR the title-based stewardship block; filtered to articles and reviews, English, 2000-2026.
Component query (this chapter)TS=("medication label*" OR "syringe label*" OR "labeling of medication*" OR "labelling of medication*" OR "unlabeled syringe*" OR "unlabelled syringe*" OR "sterile field" OR "perioperative medication*" OR "intraoperative medication*" OR "anesthesia medication*" OR "anaesthesia medication*" OR "anesthetic drug error*" OR "anaesthetic drug error*" OR "drug administration error*") OR (TS=(perioperative OR intraoperative OR anesthesi* OR anaesthesi* OR "operating room*" OR "procedural setting*") AND TS=(label* OR syringe*)), combined with the core medication safety block
Core blockTS=("medication safety" OR "medication error*" OR "medication mistake*" OR "drug error*" OR "prescribing error*" OR "prescription error*" OR "dispensing error*" OR "administration error*" OR "transcription error*" OR "adverse drug event*" OR "preventable adverse drug*" OR "medication-related harm" OR "medication incident*" OR "medication management" OR "medication use process" OR "safe medication" OR "high-alert medication*" OR "wrong drug" OR "wrong dose" OR "wrong route")
Search date and span16 November 2026; publication years 2000-2026 (2027 early-access records retained)
Inclusion and exclusionIncluded: hospital-context records matching this component. Excluded: retracted publications and records whose only labeling match was “open-label”.
Screening countsSeries corpus 4,936; tagged for this component 306; excluded 4; eligible 302; core evidence set (component term in title or author keywords) 105; “patient safety” framed 101.
Evidence extractionDefinitions, milestones, models, measures, debates and gaps were extracted from the abstracts of the most cited and most recent records in the core set.
LimitationsSingle database; English only; component tagging is rule based and reproduces the WoS query on title, abstract and keywords (agreement within 5 records per component); evidence read at abstract level; full texts were not read.
Perioperative and Procedural Medication Labeling: from the series corpus to the evidence setIdentification: 4,936 recordsWoS Core Collection, set #24, 16 Nov 2026Component tagging: 306 recordsComponent query re-applied to TI, AB, AK, KPEligible component subcorpus: 302101 also use "patient safety" framingCore evidence set: 105 recordsComponent term in title or author keywordsExcluded: 4 recordsRetracted publication or “open-label”match only (label noise)Background layer: 197Match in abstract or Keywords Plus only
Figure 1. Flow of records for Part 4. Counts match the screening sheet of the supplementary workbook. Source: produced by the author from the corpus.

1. Introduction

During elective surgery a seven-year-old boy was mistakenly injected with 100 times the intended dose of epinephrine and died the next day; unlabeled solutions on the sterile field were at the origin of the confusion (Sheridan, 2006). Cases like this explain why NPG #14 contains a precise labeling rule for perioperative and procedural settings (Joint Commission, 2025).

The perioperative environment combines high-alert drugs, many syringes prepared in advance, time pressure and frequent handovers. A prospective observation of 277 operations found a medication error or adverse drug event in 5.3% of 3,671 administrations; most errors were preventable and many had potential for harm (Nanji et al., 2016). This chapter explains how labeling fits into the broader effort to make these administrations safe.

2. History and development

Anaesthesia was among the first specialties to measure drug administration errors directly. Studies from New Zealand in 2001 (Webster et al., 2001), South Africa in 2009 (Llewellyn et al., 2009) and China in 2013 (Zhang et al., 2013) all found that errors were more frequent than previously reported. In parallel, studies in intensive care and general wards established drug administration error as a measurable category (Berdot et al., 2013; Van Den Bemt et al., 2002).

Labeling in sterile settings was translated into hospital policy by 2006 (Sheridan, 2006). From 2015, technology entered: barcode-based syringe labeling in anaesthesia (Jelacic et al., 2015), prefilled syringes (Benhamou et al., 2017; Yang et al., 2016) and label design experiments (Estock et al., 2018). The European Board of Anaesthesiology updated its recommendations in 2017 with an emphasis on correct labeling (Whitaker et al., 2017), and the Association of Anaesthetists issued guidelines on handling injectable medications in 2023 (Kinsella et al., 2023). NPG #14 lists the labeling elements explicitly (Joint Commission, 2025).

Milestones: Perioperative and Procedural Medication Labeling2001Anaesthesia errorfrequency higher thanreported2006Sterile-field labelingpolicy after fatalerror2009South Africananaesthesia errorsurvey2013Systematic review ofadministration errors2015Barcode syringe labelsystem20161 in 20 perioperativeadministrations witherror2017EBA recommendationsupdate2023Guidelines oninjectable medicines;Tall Man trial2025Labeling elements inNPG #14
Figure 2. Milestones drawn from the Joint Commission fact sheet and dated corpus records cited in this section. Source: produced by the author from the corpus.

3. Definitions and conceptual schema

Definitions concern the error (what labeling prevents) and the label (what it must contain).

SourceYearDisciplineDefinition (paraphrased)Emphasised dimension
Joint Commission (2025)2025AccreditationAll medications and solutions on and off the sterile field are labeled with name, strength, amount, diluent and volume, and expiry, when transferred and as soon as prepared.Completeness and timing
Sheridan (2006)2006Perioperative nursingUnlabeled solutions and medications during sterile procedures are a source of serious medication errors; labeling policy covers syringes and basins.Sterile procedural settings
Nanji et al. (2016)2016AnaesthesiologyPerioperative medication errors and adverse drug events expressed as a percentage of observed administrations.Frequency by direct observation
Larmené-Beld et al. (2018)2018Clinical pharmacologyUnclear labeling is an important cause of look-alike medication errors.Readability and look-alike risk
Jelacic et al. (2015)2015Anaesthesia informaticsMany anaesthetic drug errors result from vial or syringe swaps, which barcode scanning and printed labels aim to prevent.Technology-supported identification
Table 1. Definition comparison.

The shared core is that a drug separated from its original packaging must remain identifiable until it reaches the patient. Definitions diverge on whether the emphasis is on content (what the label says), design (how readable it is), timing (when the label is applied) or technology (how the label is produced and checked).

Conceptual schema: Perioperative and Procedural Medication LabelingContent: name, strength,amount, diluentTiming: as soon as preparedDesign: readability, TallMan, colourTechnology: barcode, printedlabelsPrefilled, ready-to-usesyringesSetting: on and off thesterile fieldPerioperative labelingevery drug out of its originalpackage stays identifiable
Figure 3. The shared core of the definitions (centre) and the dimensions on which they diverge (outer boxes). Source: produced by the author from the corpus.

4. Distinguishing neighbouring concepts

Labeling is one of several safeguards against wrong-drug errors in the operating room. Barcode label systems scan the vial and print the syringe label (Jelacic et al., 2015); prefilled syringes remove the preparation step (Yang et al., 2016); Tall Man lettering and colour coding change the design of the label (Da Rocha et al., 2021; Lohmeyer et al., 2023); workspace organisation such as medication templates or syringe brackets standardises where syringes are placed (Grigg et al., 2017; Long et al., 2019).

Labeling is the minimum common to all: even a barcode system or prefilled syringe still relies on a correct, readable label.

Neighbouring concepts comparedRequired by NPG#14Removespreparation stepImprovesreadabilityNeeds technologyPrevents syringeswapManual labeling of allcontainersBarcode label systemPrefilled syringesTall Man lettering and colourWorkspace organisationcentral featurepartial or context-dependentnot a defining feature
Figure 4. Distinguishing criteria between the focal concept (first row) and neighbouring concepts. Source: produced by the author from the corpus.

5. Types and classifications

Errors that labeling targets can be classified by mechanism.

MechanismExampleCorpus source
Unlabeled containerBasin or syringe on the sterile field without a label(Sheridan, 2006)
Syringe or vial swapWrong syringe picked from a tray(Jelacic et al., 2015; Webster et al., 2001)
Look-alike labelSimilar names or packaging confused(Larmené-Beld et al., 2018; Lohmeyer et al., 2023)
Dose and concentration errorWrong dilution or amount(Nanji et al., 2016)
Wrong timingOmitted or repeated dose (for example antibiotics)(Boytim & Ulrich, 2018)
Table 2. Error mechanisms addressed by labeling.

6. Theoretical frameworks and models

The literature relies on human factors engineering: medication delivery is analysed as a sequence of tasks in which safety violations can be removed by design, for example with prefilled syringes (Yang et al., 2016), and labels can be redesigned to support correct selection in a crisis (Estock et al., 2018). Eye-tracking studies apply the same logic to how nurses read syringe labels (Lohmeyer et al., 2023).

A second frame is system versus practitioner responsibility: guidelines stress that avoiding errors is both system-based and practitioner-based and requires collaboration across departments (Kinsella et al., 2023). Digital health and decision support form a third, newer frame (Nanji et al., 2022; Ye, 2023).

7. Themes and bibliometric profile

The eligible subcorpus holds 302 records (48 of them reviews) with 5,945 citations in the WoS Core Collection. 48 records appeared in 2000-2010 and 206 in 2016-2026, so most of the evidence is recent (Figure 5). The leading journals are Journal of Patient Safety (9), British Journal of Anaesthesia (8), Anesthesia and Analgesia (8), Anaesthesia (7). By author address the most active countries are United States (114), England (34), Australia (19), China (17), Germany (14). The most frequent author keywords are: medication errors, patient safety, medication safety, medication error, perioperative medication management, perioperative, anaesthesia, anesthesia, human factors, safety. 101 records (33%) explicitly frame their topic with the term “patient safety”.

Themes include (1) direct observation of anaesthetic errors (Llewellyn et al., 2009; Nanji et al., 2016; Webster et al., 2001; Zhang et al., 2013); (2) technology for identification (Jelacic et al., 2015; Thomas et al., 2022); (3) label design and LASA (Da Rocha et al., 2021; Larmené-Beld et al., 2018); (4) guidelines and professional standards (Kinsella et al., 2023; Whitaker et al., 2017); (5) perioperative medication management beyond the operating room, including pharmacists and continuation of chronic drugs (Hale et al., 2013).

Publications per year: Perioperative and Procedural Medication Labeling061320262000: 120002001: 52002: 22003: 32004: 12005: 520052006: 32007: 22008: 62009: 122010: 820102011: 122012: 102013: 122014: 62015: 820152016: 182017: 192018: 112019: 132020: 1520202021: 152022: 212023: 262024: 252025: 192026: 242026Records per publication year (n = 302); 2026 is a partial year (lighter bar). 2027 early-access records are omitted.
Figure 5. Annual output of the eligible subcorpus, 2000-2026. Source: produced by the author from the corpus.

8. The situation in Türkiye

Three records in the labeling subcorpus have a Turkish address. One is the European Board of Anaesthesiology recommendations with a Turkish co-author (Whitaker et al., 2017); another describes a robotic system for preparing intravenous solutions (Unluturk et al., 2018). No Turkish study measures labeling compliance or perioperative error rates, so the local evidence base for this requirement is thin.

9. Debates and contradictions in the literature

Axis 1: how frequent are errors? Self-reported surveys underestimate them; direct observation consistently finds higher rates (Nanji et al., 2016; Webster et al., 2001). The gap means that incident reports cannot be used to judge whether labeling policies work.

Axis 2: does technology solve the problem? Barcode label systems are feasible, but scanning at the time of administration remained moderate and needed incentives (Jelacic et al., 2015). Prefilled syringes improved safety in a human-factors study but introduced new complexity (Yang et al., 2016).

Axis 3: does label design matter in real life? Laboratory studies support Tall Man lettering, but reviewers note that evidence from real settings is scarce (Larmené-Beld et al., 2018); an in situ simulation found that Tall Man changed visual attention and helped nurses avoid errors (Lohmeyer et al., 2023), while a medication template reduced errors but not harmful errors (Grigg et al., 2017).

10. Measurement problems

Error rates depend on the method: anonymous self-report (Webster et al., 2001), direct observation with chart review (Nanji et al., 2016) and incident reporting give very different values. A systematic review called for a common denominator (total opportunities for error) and common definitions (Berdot et al., 2013).

Labeling compliance itself is rarely measured; most studies measure downstream errors. Simulation studies provide controlled measures but limited external validity (Estock et al., 2018).

11. Research gaps and agenda

The following questions are framed so that they can be answered by empirical studies; each notes the evidence gap it derives from.

  1. What is the observed compliance with the five NPG #14 label elements in operating theatres? (Compliance is rarely measured.)
  2. Do labeling policies reduce harmful perioperative errors, not only total errors? (Templates reduced errors but not harm.)
  3. How can barcode scanning at the point of administration be sustained without incentives? (Moderate scanning rates.)
  4. Are LASA label strategies effective in real operating rooms? (Evidence is mostly laboratory based.)
  5. What is the cost-effectiveness of prefilled syringes compared with labeling alone? (Budget impact studies are country specific.)
  6. What are perioperative error rates in Turkish hospitals? (No Turkish observational study.)

12. Relevance today and practical implications

An operating theatre can operationalise the requirement through: sterile marker pens and preprinted sterile labels available in every tray (Sheridan, 2006); a rule that nothing leaves its original container without a label; preference for ready-to-use or prefilled syringes for emergency drugs (Benhamou et al., 2017); standard placement of syringes on the anaesthesia workstation (Grigg et al., 2017); and a quarterly observational audit of the five label elements with feedback (Joint Commission, 2025).

Summary box

  • NPG #14 requires all medications and solutions in perioperative and procedural settings to be labeled with five elements.
  • Direct observation finds an error or adverse drug event in about 5% of perioperative administrations.
  • Syringe swaps, unlabeled containers and look-alike labels are the main mechanisms.
  • Barcode label systems and prefilled syringes help but depend on consistent use.
  • Label design evidence is strong in the laboratory and weaker in real settings.
  • Turkish evidence on perioperative labeling is very limited in the corpus.

Discussion questions

  1. Why is the sterile field a particular source of unlabeled medications?
  2. Compare self-report and direct observation as ways of measuring anaesthetic drug errors.
  3. What can a prefilled syringe prevent that a label cannot?
  4. Why might a medication template reduce errors but not harmful errors?
  5. Application: design a five-item observational checklist for labeling compliance.
  6. Application: propose how to introduce barcode syringe labeling in a hospital with limited budget.

Further reading

  • Nanji et al. (2016): the reference observational study on perioperative errors.
  • Sheridan (2006): a short practical account of sterile-field labeling.
  • Jelacic et al. (2015): lessons from implementing barcode syringe labels.
  • Kinsella et al. (2023): current professional guidance on injectable medicines in anaesthesia.
  • Larmené-Beld et al. (2018): review of strategies against look-alike labels.

Glossary

TermTurkishShort definition
Sterile fieldSteril alanArea kept free of micro-organisms during a procedure.
Syringe swapEnjektör karışmasıAdministration from the wrong syringe.
Prefilled syringeÖnceden doldurulmuş enjektörReady-to-use syringe prepared by manufacturer or pharmacy.
Tall Man letteringBüyük harf vurgulamaUse of capitals to highlight differences in similar drug names.
Drug administration errorİlaç uygulama hatasıDifference between the drug given and the drug intended.
Barcode label systemBarkodlu etiket sistemiScanning vials to print and verify syringe labels.
PerioperativePerioperatifBefore, during and after surgery.

References

Benhamou, D., Piriou, V., De Vaumas, C., Albaladejo, P., Malinovsky, J. M., Doz, M., Lafuma, A., & Bouaziz, H. (2017). Ready-to-use pre-filled syringes of atropine for anaesthesia care in French hospitals – a budget impact analysis. Anaesthesia Critical Care & Pain Medicine, 36(2), 115-121. https://doi.org/10.1016/j.accpm.2016.03.009

Berdot, S., Gillaizeau, F., Caruba, T., Prognon, P., Durieux, P., & Sabatier, B. (2013). Drug Administration Errors in Hospital Inpatients: A Systematic Review. PLOS One, 8(6), e68856. https://doi.org/10.1371/journal.pone.0068856

Boytim, J., & Ulrich, B. (2018). Factors Contributing to Perioperative Medication Errors: A Systematic Literature Review. AORN Journal, 107(1), 91-107. https://doi.org/10.1002/aorn.12005

Da Rocha, B. S., Moraes, C. G., Okumura, L. M., Da Cruz, F., Sirtori, L., & Pons, E. D. (2021). Interventions to Reduce Problems Related to the Readability and Comprehensibility of Drug Packages and Labels: A Systematic Review. Journal of Patient Safety, 17(8), E1494-E1506. https://doi.org/10.1097/PTS.0000000000000619

Estock, J. L., Murray, A. W., Mizah, M. T., Mangione, M. P., Goode, J. S., & Eibling, D. E. (2018). Label Design Affects Medication Safety in an Operating Room Crisis: A Controlled Simulation Study. Journal of Patient Safety, 14(2), 101-106. https://doi.org/10.1097/PTS.0000000000000176

Grigg, E. B., Martin, L. D., Ross, F. J., Roesler, A., Rampersad, S. E., Haberkern, C., Low, D. K. W., Carlin, K., & Martin, L. D. (2017). Assessing the Impact of the Anesthesia Medication Template on Medication Errors During Anesthesia: A Prospective Study. Anesthesia and Analgesia, 124(5), 1617-1625. https://doi.org/10.1213/ANE.0000000000001823

Hale, A. R., Coombes, I. D., Stokes, J., McDougall, D., Whitfield, K., Maycock, E., & Nissen, L. (2013). Perioperative medication management: expanding the role of the preadmission clinic pharmacist in a single centre, randomised controlled trial of collaborative prescribing. BMJ Open, 3(7), e003027. https://doi.org/10.1136/bmjopen-2013-003027

Jelacic, S., Bowdle, A., Nair, B. G., Kusulos, D., Bower, L., & Togashi, K. (2015). A System for Anesthesia Drug Administration Using Barcode Technology: The Codonics Safe Label System and Smart Anesthesia Manager™. Anesthesia and Analgesia, 121(2), 410-421. https://doi.org/10.1213/ANE.0000000000000256

Joint Commission. (2025). Effectively managing medications (National Performance Goal #14) [Fact sheet]. https://digitalassets.jointcommission.org/api/public/content/d0c3745c2d7e494ca5199bd3af2a13bc

Kinsella, S. M., Boaden, B., El-Ghazali, S., Ferguson, K., Kirkpatrick, G., Meek, T., Misra, U., Pandit, J. J., & Young, P. J. (2023). Handling injectable medications in anaesthesia Guidelines from the Association of Anaesthetists. Anaesthesia, 78(10), 1285-1294. https://doi.org/10.1111/anae.16095

Larmené-Beld, K. H. M., Alting, E. K., & Taxis, K. (2018). A systematic literature review on strategies to avoid look-alike errors of labels. European Journal of Clinical Pharmacology, 74(8), 985-993. https://doi.org/10.1007/s00228-018-2471-z

Llewellyn, R. L., Gordon, P. C., Wheatcroft, D., Lines, D., Reed, A., Buttt, A. D., Lundgren, A. C., & James, M. F. M. (2009). Drug administration errors: a prospective survey from three South African teaching hospitals. Anaesthesia and Intensive Care, 37(1), 93-98. https://doi.org/10.1177/0310057X0903700105

Lohmeyer, Q., Schiess, C., Garcia, P. D. W., Petry, H., Strauch, E., Dietsche, A., Schuepbach, R. A., Buehler, P. K., & Hofmaenner, D. A. (2023). Effects of tall man lettering on the visual behaviour of critical care nurses while identifying syringe drug labels: a randomised in situ simulation. BMJ Quality & Safety, 32(1), 26-33. https://doi.org/10.1136/bmjqs-2021-014438

Long, D. R., Doney, A., Bartels, D. L., Tan, C. E., Sayal, P. K., Anderson, T. A., & Agarwala, A. V. (2019). Anesthesia Workspace Cleanliness and Safety: Implementation of a Novel Syringe Bracket Using 3D Printing Techniques. Anesthesiology Research and Practice, 2019, 2673781. https://doi.org/10.1155/2019/2673781

Nanji, K. C., Garabedian, P. M., Langlieb, M. E., Rui, A., Tabayoyong, L. L., Sampson, M., Deng, H., Boxwala, A., Minehart, R. D., & Bates, D. W. (2022). Usability of a perioperative medication-related clinical decision support software application: a randomized controlled trial. Journal of the American Medical Informatics Association, 29(8), 1416-1424. https://doi.org/10.1093/jamia/ocac035

Nanji, K. C., Patel, A., Shaikh, S., Seger, D. L., & Bates, D. W. (2016). Evaluation of Perioperative Medication Errors and Adverse Drug Events. Anesthesiology, 124(1), 25-34. https://doi.org/10.1097/ALN.0000000000000904

Sheridan, D. J. (2006). Labeling Solutions and Medications in Sterile Procedural Settings. Joint Commission Journal on Quality and Patient Safety, 32(5), 276-282. https://doi.org/10.1016/S1553-7250(06)32036-3

Thomas, J. J., Bashqoy, F., Brinton, J. T., Guffey, P., & Yaster, M. (2022). Integration of the Codonics Safe Label System(R) and the Omnicell XT(R) Anesthesia Workstation into Pediatric Anesthesia Practice: Utilizing Technology to Increase Medication Labeling Compliance and Decrease Medication Discrepancies While Maintaining User Acceptability. Hospital Pharmacy, 57(1), 11-16. https://doi.org/10.1177/0018578720970464

Unluturk, M. S., Tamer, O., & Utku, S. (2018). A robotic system to prepare IV solutions. International Journal of Medical Informatics, 119, 61-69. https://doi.org/10.1016/j.ijmedinf.2018.09.011

Van Den Bemt, P. M. L. A., Fijn, R., Van Der Voort, P. H. J., Gossen, A. A., Egberts, T. C. G., & Brouwers, J. R. B. J. (2002). Frequency and determinants of drug administration errors in the intensive care unit. Critical Care Medicine, 30(4), 846-850. https://doi.org/10.1097/00003246-200204000-00022

Webster, C. S., Merry, A. F., Larsson, L., McGrath, K. A., & Weller, J. (2001). The frequency and nature of drug administration error during anaesthesia. Anaesthesia and Intensive Care, 29(5), 494-500. https://doi.org/10.1177/0310057X0102900508

Whitaker, D., Brattebo, G., Trenkler, S., Vanags, I., Petrini, F., Aykac, Z., Longrois, D., Loer, S. A., Gaszynski, T., Sipylaite, J., Copaciu, E., Cerny, V., Akeson, J., Mellin-Olsen, J., Abela, C., Stecher, A., Kozek-Langenecker, S., & Rätsep, I. (2017). The European Board of Anaesthesiology recommendations for safe medication practice First update. European Journal of Anaesthesiology, 34(1), 4-7. https://doi.org/10.1097/EJA.0000000000000531

Yang, Y. S., Rivera, A. J., Fortier, C. R., & Abernathy, J. H. (2016). A Human Factors Engineering Study of the Medication Delivery Process during an Anesthetic Self-filled Syringes versus Prefilled Syringes. Anesthesiology, 124(4), 795-803. https://doi.org/10.1097/ALN.0000000000001040

Ye, J. C. (2023). Patient Safety of Perioperative Medication Through the Lens of Digital Health and Artificial Intelligence. JMIR Perioperative Medicine, 6, e34453. https://doi.org/10.2196/34453

Zhang, Y., Dong, Y. J., Webster, C. S., Ding, X. D., Liu, X. Y., Chen, W. M., Meng, L. X., Wu, X. Y., & Wang, D. N. (2013). The frequency and nature of drug administration error during anaesthesia in a Chinese hospital. Acta Anaesthesiologica Scandinavica, 57(2), 158-164. https://doi.org/10.1111/j.1399-6576.2012.02762.x

Source verification note

Author names, year, journal and DOI details of the 24 corpus-based citations were generated by code directly from the Web of Science records and checked one to one against the in-text citations; claims were checked at the level of record abstracts, and full texts were not read. The Joint Commission fact sheet was read in full on 16 November 2026. No source outside the corpus and the fact sheet is cited.

AI use statement

Anthropic’s Claude model was used to design and run the Web of Science search, tag and pre-screen records, extract evidence from abstracts, draft the English text and produce the figures. Final decisions, the scientific accuracy of the text and final responsibility rest with the author.

Data and supplementary material

The full list of the 105 core records and the 302 eligible records for this part (author, year, title, journal, DOI, component flags, “patient safety” layer flag and pre-screening suggestion), the screening log of the 4,936-record series corpus and the citation verification report are provided in the series companion workbook (NPG14_Series_Supplementary.xlsx), available from the author on request. The record list is deliberately kept out of the chapter text.

Cite this page (APA 7)

Kurutkan, M. N. (2026, November 16). Perioperative and Procedural Medication Labeling: An Introduction (101). The Health Topics. https://healthtopic.org/topics/perioperative-and-procedural-medication-labeling-an-introduction-101/

Subscribe to the Health Topics Newsletter!

Google reCaptcha: Invalid site key.